Rental/Sales
800 399-4CEM
(800 399-4236)

|
 Teledyne-API Model 200EH/EM
Chemiluminescent NO/NO2/NOxAnalyzer


The Models 200EH and 200EM use the proven chemiluminescence measurement principle, coupled with state-of-the-art microprocessor technology for monitoring high and medium levels of nitrogen oxides. User-selectable analog output ranges and a linear response over the entire measurement range make them ideal for a wide variety of applications, including extractive and dilution CEM, stack testing, and process control.
A choice of NO2 converters handles tough CEM and stack testing as well as combustion turbine startup and continuous operation applications. Selectable measurement modes (NOX only, NO only, NO/NOX switching), auto ranging (single range, dual range, auto-range, independent ranges, remote range control) enables to match the Models 200EH or 200EM to your needs.
Modular instrument design offers top-mounted, quick access to all subassemblies and hinged front and rear panels to simplify module replacement and maintenance. A standard permeation dryer on the ozone generator provides dry air and excess ozone is removed by catalytic reaction, both eliminating the need for expendables.
All instruments in the Teledyne-API Model “E”- Series include built-in data acquisition capability with internal memory. This allows logging of multiple parameters in different predefined or customized data channels including averaged or instantaneous concentration values, calibration data, and operating parameters such as pressures and flow rates.
Stored data are easily retrieved through the RS-232 port via APICOM or from the front panel, allowing predictive diagnostics and enhanced data analysis by tracking parameter trends. The Models 200EH and 200EM combine rugged construction, light weight, ease of use, powerful diagnostics and outstanding performance for high and medium range applications.
| Specifications |
| Ranges: |
200EH: 0-5 ppm to 0-5000 ppm full scale, user selectable; independent NO, NO2, NOX ranges and auto-ranging supported
200EM: 0-1 ppm to 0-200 ppm |
| Units: |
ppm, mg/m3 |
| Zero noise: |
< 20 ppb (RMS) |
| Span noise: |
< 0.2% of reading above 20 ppm (RMS) |
| Lower Detectable Limit (LDL): |
< 40 ppb (RMS) |
| Zero drift: |
< 20 ppb/24 hours |
| Span drift: |
< 1% reading / 24 hours, < 1% reading / 7 days |
| Lag time: |
20 seconds switching mode; < 6 seconds NO or NOX only mode |
| Rise and Fall Time: |
< 60 seconds to 95% (switching); 5 seconds NO only; 10 seconds NOX only |
| Linearity: |
1% of full scale |
| Precision: |
0.5% of reading |
| Sample Flow Rate: |
250 cm3/min (standard); 500 cm/min (optional) |
| Operating Temperature Range: |
5 - 40° C |
| Dimensions (HxWxD): |
7” (178 mm) x 17” (432 mm) x 23.5” (597 mm) |
| Weight: |
Analyzer - 44 lbs (20 kg)
External pump - 15 lbs (7 kg) |
| Power: |
100V 50/60 Hz, 115V 60Hz, 220V 50/60Hz, 230V 50Hz, 240V 50Hz, 250 Watts (analyzer), 250 Watts (pump) |
| Analog outputs: |
10V, 5V, 1V, 0.1V, selectable |
| Recorder Offset: |
±10% |
| Serial Outputs: |
Serial Port 1: RS-232 (DB-9M)
Serial Port 2: standard RS-232 or optional RS-485 (DB-9F) |
| Status (Digital): |
8 outputs, 6 inputs (opto-isolated), 6 alarm outputs (optional) |
| Current Output: |
0-20 mA or 4-20 mA isolated outputs (optional) |
| Approvals: |
CE |
For availability and recommendations, please call us at 800.399.4236 or email a Sales Engineer.
Or click on the RFQ link to submit project details.
|