rfqrfqTeledyne-API Model 360E
Gas Correlation CO2 Analyzer










The Model 360E measures carbon dioxide CO2 by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law. This is accomplished by using a Gas Filter Wheel which alternately allows a high energy infrared light source to pass through a CO2 filled chamber and a chamber with no CO2 present. The light then travels through the sample cell, which has a folded path. The energy loss through the sample cell is compared with the zero reference signal provided by the gas filter to produce an output proportional to concentration, with little effect from interfering gases within the sample. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.

This design produces superior zero and span stability and a high signal-to-noise ratio, allowing excellent sensitivity. Multi-tasking software gives real time indication of numerous operating parameters and provides automatic alarms if diagnostic limits are exceeded. Built-in data acquisition and internal memory allows logging multiple parameters including average and instantaneous values, calibration data, and operating parameters. Stored data can be retrieved via the RS-232 port, ethernet, or from the front panel. The Model 360E features rugged construction and is designed to perform with a minimum of attention. Regular maintenance is greatly simplified through the use of modularization construction.

Specifications:
Ranges: 0-2 ppm to 0-2000 ppm full scale, user selectable
Dual ranges and auto ranging supported
Units: ppb, ppm, μg/m3, mg/m3, %
Zero Noise: < 0.1 ppm (RMS)
Span Noise: < 1.0% of reading above 100 ppm (RMS)
Lower Detectable Limit (LDL): 0.2 ppm
Zero Drift: < 0.25 ppm/24 hours, < 0.5 ppm/7 days
Span Drift: < 0.5% of reading/24 hours, < 1% of reading/7 days
Lag Time: 10 seconds
Rise and Fall Time: < 60 seconds to 95%
Linearity: 1% of full scale
Precision: 0.5% of reading
Sample Flow Rate: 800 cc/min ±10%
Operating Temperature Range: 5 - 40°C
Dimensions (HxWxD): 7” (178 mm) x 17” (432 mm) x 23.5” (597 mm)
Weight: 40 lbs (17 kg)
Power: 100V - 120V, 220V - 240V, 50/60 Hz, 250W
Analog Outputs: 10V, 5V, 1V, 100 mV, selectable
Current Output: Optional 4-20 mA isolated outputs (select up to 3 channels)
Recorder Offset: ±10%
Serial Outputs: Serial Port 1: RS-232 (DB-9M)
Serial Port 2: standard RS-232 or optional
RS-485 (DB-9F), Ethernet
Status (Digital) 8 outputs, 6 inputs (opto-isolated), 4 alarm outputs (optional)
Approvals: CE

NOTE: The values expressed above are in accordance with EPA definitions. All error specifications are based on constant conditions.